No. |
Index |
Value |
| 1 |
Bearing dimensions, mm |
|
| Outer Ø |
250 |
| Width, mm |
80 |
| 2 |
Capacity, piece/h |
60 |
| 3 |
Amount of rows (amount of bearings treated
simultaneously) |
2 |
| 4 |
Amount of washing sections |
1 |
| 5 |
Amount of drying sections |
1 |
| 6 |
Washing and drying time for 1 pair of
bearings, min |
2- 4 |
| 7 |
Bearing rotating speed by washing and
drying, RPM |
100 |
| 8 |
Rotating drive power, kW |
1,1 |
| 9 |
Washing agent temperature, °С |
40- 95 |
| 10 |
Pump pressure, MPa (kgf/cm²) |
0,32 (3,2) |
| 11 |
Pump capacity of washing agent feed, m³/h |
25 |
| 12 |
Pump drive power, kW |
5,5 |
| 13 |
Washing agent mass in the tank, kg |
1000 |
| 14 |
Tank volume, m³ |
115 |
| 15 |
Tank dimensions, mm |
2200х700х750 |
| 16 |
Water vapour pressure, MPa (kgf/cm²)
|
0,3 (3) |
| 17 |
Dry water vapour consumption by its
condensation to moisture of 50%, kg/h |
35 |
| 18 |
Amount of electrical heaters |
9 |
| 19 |
Total power of electrical heating, kW |
31 5 |
| 20 |
Voltage, V |
380/220 |
| 21 |
Bearing drying |
From air net |
| 22 |
Air pressure, MPa (kgf/cm²) |
0,4-0,6 (4,0-6,0) |
| 23 |
Air consumption for bearing drying, m³/h
|
100 |
| 24 |
Air pressure in the control system, MPa (kgf/cm²)
|
0,4-0,6 (4,0-6,0) |
| 25 |
Air consumption in the control system, l/h
|
60 |
| 26 |
Plant weight without washing agent, kg |
1000 |